Technical Data
| Line laser | GLL 50-15 XG | 
|---|---|
| Article number | 3 601 K65 7.. | 
| Working rangeA) | |
| 
 | 15 m | 
| 
 | 10 m | 
| 
 | 5–50 m | 
| 
 | 5 m | 
| Levelling accuracyB)C)D) | |
| 
 | ±0.2 mm/m | 
| 
 | ±0.3 mm/m | 
| 
 | ±0.7 mm/m | 
| Self-levelling range | ±2.5° | 
| Levelling time | < 4 s | 
| Operating temperature | –10 °C to +45 °C | 
| Storage temperature | –20 °C to +70 °C | 
| Max. altitude | 2000 m | 
| Relative air humidity max. | 90% | 
| Pollution degree according to IEC 61010-1 | 2E) | 
| Laser class | 2 | 
| Laser line | |
| 
 | < 10 mW, 500–540 nm | 
| 
 | Green | 
| 
 | 10 | 
| 
 | 50 × 10 mrad (full angle) | 
| Plumb point | |
| 
 | < 1 mW, 630–650 nm | 
| 
 | Red | 
| 
 | 1 | 
| 
 | 0.8 mrad (full angle) | 
| Pulse frequency | |
| 
 | 23 kHz | 
| 
 | 10 kHz | 
| Tripod mountF) | 5/8" | 
| Batteries | 4 × 1.5 V LR6 (AA) | 
| Weight (with batteries) | 0.54 kg | 
| Dimensions (length × width × height) | |
| 
 | 122 × 83 × 129 mm | 
| 
 | Dia. 151 × 203 mm | 
| Protection rating (excluding battery compartment) | IP54 | 
- A)
- The working range may be reduced by unfavourable environmental conditions (e.g. direct sunlight). 
- B)
- At 20–25 °C 
- C)
- The values stated presuppose normal to favourable environmental conditions (e.g. no vibration, no fog, no smoke, no direct sunlight). Extreme fluctuations in temperature can cause deviations in accuracy. 
- D)
- An additional deviation of ±0.1 mm/m must be taken into account when at maximum self-levelling range. 
- E)
- Only non-conductive deposits occur, whereby occasional temporary conductivity caused by condensation is expected. 
- F)
- Only available in combination with the rotating platform 
The serial number (4) on the type plate is used to clearly identify your measuring tool.