Technical data
| Digital detector | GMS 120‑27 | 
|---|---|
| Article number | 3 601 K81 7.. | 
| Max. detection depthA) | |
| 
 | 120 mmB) | 
| 
 | 100 mmC) | 
| 
 | 50 mmD) | 
| 
 | 30 mmE) | 
| Operating temperature | –10 °C to +50 °C | 
| Storage temperature | –20 °C to +70 °C | 
| Operating frequency range | 50 ± 2 kHz | 
| Max. magnetic field strength (at 10 m) | 42 dBµA/m | 
| Max. altitude | 2000 m | 
| Relative air humidity max. | |
| 
 | 90 % | 
| 
 | 50 % | 
| Pollution degree according to IEC 61010-1 | 2F) | 
| Energy supply | |
| 
 | 3.7 V | 
| 
 | 2 × 1.5 V LR6 (AA) | 
| 
 | 2 × 1.2 V HR6 (AA) | 
| Operating time, approx. | |
| 
 | 5 h | 
| 
 | 6 h | 
| 
 | 7 h | 
| WeightG) | 0.24 kg | 
| Dimensions (length × width × height) | 186 × 86 × 33 mm | 
| Protection rating | IP54 | 
| Lithium-ion battery pack (accessory) | BA 3.7V 1.0Ah A | 
| Article number | 1 607 A35 17H | 
| Article number JP | 1 607 A35 0N8 | 
| Charging connection | USB Type‑C® | 
| Rated voltage | 3.7 V  | 
| Capacity | 1.0 Ah | 
| Recommended ambient temperature during charging | +10 °C to +35 °C | 
| Recommended ambient temperature during operation and during storage | –10 °C to +45 °C | 
| Power supply (accessory) | |
| Output voltage | 5.0 V  | 
| Minimum output current | 500 mA | 
- A)
- Depends on material and size of the objects, as well as material and condition of the substrate 
- B)
- For a copper pipe with a 15 mm diameter 
- C)
- For reinforcing steel with a 12 mm diameter 
- D)
- Lower detection depth with non-live wires 
- E)
- For wooden beams with a width of 54 mm, behind 30 mm thick plasterboard 
- F)
- Only non-conductive deposits occur, whereby occasional temporary conductivity caused by condensation is expected. 
- G)
- Weight without lithium-ion battery pack/non-rechargeable batteries/rechargeable batteries/battery compartment cover 
The serial number (19) on the type plate is used to clearly identify your measuring tool.
- The accuracy and detection depth of the measuring result may be negatively affected if the condition of the substrate is unfavorable.