Technical Data

Thermal imaging camera

GTC 450-13

Article number

‎3 601 K83 9K0

Resolution of infrared sensor

256 × 192 px

Thermal sensitivityA)

≤ 50 mK

Spectral range

8–14 μm

Field of view (FOV)A)

55.6° × 42°

Spatial resolution (IFOV)

3.79 mrad

Focus distanceA)

≥ 0.5 m

Focus

Fixed

Thermal image refresh rate

≤ 9 Hz

Surface temperature measuring rangeA)

–20 °C to +450 °C

Surface temperature measuring accuracyA)B)C)
> 0 °C to ≤ +100 °CD)
> +100 °CE)


±2 °C
±2 %

Temperature resolution

0.1 °C

Display type

TFT

Display size

2.8"

Display resolution

480 × 360 px

Integrated visual camera resolution

2 MP (640 × 480 px)

Image format

.jpg

Elements saved per saving process

1 × thermal image (screenshot)
1 × real visual image incl. temperature values (metadata)

Max. number of images in internal image memory

500

Max. altitude

2000 m

Pollution degree according to IEC 61010-1

2F)

Max. relative humidityA)

90 %

Laser class

2

Laser type

< 1 mW, 645−660 nm

Divergence of the laser beam

1.5 mrad (full angle)

Power supply

  • Rechargeable battery pack (Li-ion)

10.8 V/12 V

  • Non-rechargeable batteries (alkaline manganese, with battery adapter)

4 × 1.5 V LR6 (AA)

  • Rechargeable batteries (NiMH, with battery adapter)

4 × 1.2 V HR6 (AA)

Operating timeG)

  • Rechargeable battery pack (Li-ion)H)I)

8 h

  • Non-rechargeable batteries (alkaline manganese)

4 h

System time power supply

CR1225 (3 V lithium battery)

USB standard

2.0

USB Port

USB Type-C®

WeightJ)

0.354 kg

Dimensions (length × width × height)K)

89 × 79 × 209 mm

Protection rating (excluding [rechargeable] batteries, in the vertical position)

IP54

Recommended ambient temperature during charging

0 °C to +35 °C

Permitted ambient temperatures

  • During operation

–10 °C to +50 °C

  • During storage with a rechargeable battery

–20 °C to +50 °C

  • During storage without a rechargeable battery

–20 °C to +70 °C

Recommended rechargeable batteries

GBA 10.8V…
GBA 12V…

Recommended battery chargers

GAL 12…
GAX 18…

A)

In accordance with standard VDI 5585 (average)

B)

At an ambient temperature of 20–23 °C and an emissivity of ≥ 0.95, measuring distance: 1 m, operating time: > 5 min, aperture of 150 mm, with the worklight and laser switched off

C)

Plus use-dependent deviation (e.g. reflection, distance, ambient temperature)

D)

Applies to the centre point, all other pixels additionally ±1 °C

E)

Applies to the centre point, all other pixels additionally ±1 %

F)

Only non-conductive deposits occur, whereby occasional temporary conductivity caused by condensation is expected.

G)

With the worklight switched off and medium display brightness

H)

Depending on battery in use

I)

At an ambient temperature of 20–30 °C

J)

Weight without rechargeable batteries/battery adapter/non-rechargeable batteries

K)

with GBA 12V 2.0Ah or battery adapter

The serial number (20) on the type plate is used to clearly identify your measuring tool.