Working Advice
- Comply with the manufacturer's instructions regarding the greases! Certain greases can only be used in a certain temperature range.
- Open and use the cartridges in accordance with the manufacturer's specifications.
- The brackets for the shoulder strap do not act as fall protection. Use the brackets (15) only to attach a shoulder strap.
Greasing (see figure K)
- Fill the power tool with grease.
- Install the required nosepiece: (31)/(32).
- Set the required gear (switch (7)).
- If required, set the number of pump strokes (thumbwheel (2)).
- Connect the nosepiece to the lubrication point.
- Unlock the on/off switch (locking mechanism (4)).
- Switch the power tool on (on/off switch (6)).
- Once the required grease quantity has been applied to the lubrication point, switch the power tool off.
or
Once the set number of pump strokes has been reached, the power tool switches off automatically.
Pressure relief valve
The pressure relief valve (18) opens if the working pressure exceeds the maximum pressure of 10,000 psi during greasing. Grease is drained into the cap of the pressure relief valve, and the power tool switches off automatically.
- Switch the power tool off.
- Inspect the lubrication point and the hose (19) for possible blockages.
Once any faults have been rectified, work can continue as normal.