Work preparation

By preselecting the pump strokes, a constant grease quantity can be applied to various lubrication points.

  • Set the required number of pump strokes on the thumbwheel (2).

Thumbwheel (2)

Number of pump strokes

ON

Unlimited as long as the on/off switch (6) is pressed.

1 ... 50

Once the set number of pump strokes has been reached, the power tool switches off automatically, even if the on/off switch (6) continues to be pressed.

The power tool has two gears that regulate the grease flow rate in relation to the working pressure.

  • Set the required gear using the switch (7).

Switch (7)

Grease quantity/working pressure

First gear

  • Grease flow rate: 100 g/min
  • Maximum working pressure: 10000 psi

Second gear

  • Maximum grease flow rate: 320 g/min
  • Working pressure: 6000−8000 psi

Different grease quantities are applied depending on the number of pump strokes.

Number of pump strokes

Grease quantityA)[g]

1

0.7

2

1.4

3

2.1

4

2.8

5

3.5

6

4.2

7

4.9

8

5.6

9

6.3

10

7.0

15

10.5

20

14.0

25

17.5

50

35.0

A)

± 5 %